HV junction box

EBJB1500

In development

Everything the junction box needs to periodically measure, report, and control on one board.

A single controller that measures pack and link voltage, measures current through an on-board shunt, monitors isolation resistance, and drives up to four contactors. It reports state to the central controller over the 10BASE-T1S interface and switches its contactors on the controller’s command.

Central Controller 10BASE-T1S Interface Battery junction box Battery pack M Drive system Auxiliary load Contactors Shunt Isolation

What it handles

High voltage
Pack and link voltage, either side of the contactors.
Current
On-board shunt, across the full operating range from standby leakage to peak discharge.
Isolation
Continuous measurement of isolation resistance between the high-voltage system and chassis.
Contactor control
Up to four contactors.
Overcurrent
Detected inside the device and reported to the central controller.
1500 V
Rated voltage
1000 A
Continuous current
4000 A
Peak current
ASIL D
Designed to meet ISO 26262

Measurement you can build a safety case on.

The hardware is a Safety Element out of Context designed to meet ISO 26262 ASIL D. Pack current, high-voltage measurement, isolation measurement and contactor control each carry their own rating, and the host reaches all of them through a simple, configurable device driver.

One board

These functions are usually spread across three or four separate parts inside the box, each with its own wiring, its own supplier and its own safety argument. Bringing them onto one board shortens the harness and removes connectors, and it leaves a single interface to integrate, validate and qualify. The saving is in engineering effort as much as in bill of materials.

Contactors, enclosure and busbars remain yours to choose. We supply the controller.

Key features

Battery Module Board (BMB) Interface
  • A dedicated front end (BMB_IF) connects to the first of a daisy-chain of Battery Module Boards, independent of the main measurement path.
Pack current ASIL D
  • Dual-shunt measurement with continuous coulomb counting.
  • Four-channel thermal compensation (T1–T4).
HV measurement up to ASIL D
  • Five HV-capable analog channels — 3 fixed, 2 switchable.
  • On switched resistor dividers.
Isolation measurement up to ASIL D
  • Derived from the HV measurement network.
Contactor control ASIL D
  • Up to four contactors.
Host interface
  • 10BASE-T1S.

Specifications

ParameterValue
Battery Module InterfaceInterface front end (BMB_IF), daisy-chain of module boards
Continuous current1000 A
Peak current4000 A
External temperature sensing4 channels (NTC_1–4), for external NTC probes
HV analog inputs5 channels total — 3 fixed (pack voltage / isolation), 2 switchable
Contactor controlUp to 4 contactors
Host interface10BASE-T1S automotive Ethernet
Supply12 V / 24 V (KL30)
Operating temperature−40 °C to +105 °C, automotive grade
Functional safetySEooC, ASIL D target

System topology

Multiple EBJB1500 nodes share one bus, managed by the central controller.

Each EBJB1500 only measures and reports — brick voltages, pack V and I — and switches its contactors on command; it makes no trip decisions of its own. The controller reads those reports over a single multidrop 10BASE-T1S segment, decides when to open a contactor, and keeps a continuous heartbeat running to every node. If that heartbeat stops, the node opens its contactors as a fail-safe.

Central Controller BMS Controller Zonal ECU 10BASE-T1S MULTIDROP BUS PLCA · 10 Mbps EBJB1500 #1 Brick Voltages Pack V/I Contactors Hardware Keying Plug & Play EBJB1500 #2 Brick Voltages Pack V/I Contactors Hardware Keying Plug & Play EBJB1500 #3 Brick Voltages Pack V/I Contactors Hardware Keying Plug & Play EBJB1500 #4 Brick Voltages Pack V/I Contactors Hardware Keying Plug & Play FAIL-SAFE · no heartbeat from the controller opens the node’s own contactors
Central controller EBJB1500 10BASE-T1S Bus Commands · Heartbeat · Fail-safe

Detailed specifications are available on request.

Get in touch